UL 360 DXHR.E18917 / NEC Article 350 / CSA C22.2 #LL15275 / RoHS WEEE COMPLIANT
CSA Certified "Heavy Duty," CSA HD 1/2” and up / Meets requirements of NFPA 79 (2024 Edition) Section 13.5.4 LFMC and NFPA 130 (2023 Edition) Section 8.6.7.4 LFMC
Compact 316 Stainless Steel for the best corrosion resistance
Compact Nickel-Plated Brass for next level corrosion resistance
Items |
37402 Type HTUA - Higher and Lower Temperatures Liquid-Tight Flexible Metal Conduit (LFMC) |
37412 Type HTUA - Higher and Lower Temperatures Liquid-Tight Flexible Metal Conduit (LFMC) |
37422 Type HTUA - Higher and Lower Temperatures Liquid-Tight Flexible Metal Conduit (LFMC) |
37431 Type HTUA - Higher and Lower Temperatures Liquid-Tight Flexible Metal Conduit (LFMC) |
37441 Type HTUA - Higher and Lower Temperatures Liquid-Tight Flexible Metal Conduit (LFMC) |
|||||
Description |
N/A
Thermoplastic PVC jacket with integral bonding wire 3/8" through 1-1/4" Conduit shall be Anaconda SEALTITE® Type HTUA. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with an integral bonding wire in sizes 3/8" thru 1-1/4". Conduit shall have a sunlight resistant and flame retardant PVC jacket in electrical trade sizes 3/8" thru 4". Conduit shall be UL listed, CSA certified and IP 67 rated when installed with approved end connectors. |
|||||||||
Type | N/A HTUA | |||||||||
Electrical Trade Size | N/A 3/8 in12 mm | N/A 1/2 in16 mm | N/A 3/4 in21 mm | N/A 1 in27 mm | N/A 1-1/4 in35 mm | |||||
Length | N/A 100 ft30.48 m | N/A 100 ft30.48 m | N/A 100 ft30.48 m | N/A 100 ft30.48 m | N/A 50 ft15.24 m | |||||
Packaging | N/A Small Cartons | |||||||||
Inside Diameter | N/A 0.484 to 0.504 in12.294 to 12.802 mm | N/A 0.622 to 0.642 in15.799 to 16.307 mm | N/A 0.820 to 0.840 in20.828 to 21.336 mm | N/A 1.041 to 1.066 in26.441 to 27.076 mm | N/A 1.380 to 1.410 in35.052 to 35.814 mm | |||||
Outside Diameter | N/A 0.690 to 0.710 in17.526 to 18.034 mm | N/A 0.822 to 0.840 in20.879 to 21.336 mm | N/A 1.030 to 1.050 in26.162 to 26.670 mm | N/A 1.290 to 1.315 in32.766 to 33.401 mm | N/A 1.630 to 1.660 in41.402 to 42.164 mm | |||||
Approx. Inside Bend Radius | N/A 3.0 in76.2 mm | N/A 3.5 in88.9 mm | N/A 5.0 in127 mm | N/A 6.0 in152.4 mm | N/A 7.0 in177.8 mm | |||||
Approx. Weight per 100 ft | N/A 24 lbs10.89 kg | N/A 29 lbs13.15 kg | N/A 43 lbs19.5 kg | N/A 73 lbs33.11 kg | N/A 100 lbs45.36 kg | |||||
Installation |
N/A
|
|||||||||
Color | N/A GRAY | |||||||||
Optional Colors | N/A Black | |||||||||
NEC Articles |
N/A
|
|||||||||
Application |
N/A
Ideal for Use in Environments with Extreme Temperatures and UL Listing is Required Temperature Range: -51ºF to +221ºF (-46ºC to +105ºC) |
|||||||||
Industry Certifications |
N/A
UL Listed & CSA Certified |
|||||||||
Core Material | N/A Galvanized Steel | |||||||||
Ingress Protection (IP) Rating | N/A Ingress Protection (IP) 66/67 | |||||||||
Jacket Material | N/A Polyvinyl Chloride (PVC) | |||||||||
Jacket Benefits | N/A Extreme Cold High Heat Liquid Tight Oil Resistant | |||||||||
|