Thermoplastic PVC

Conduit shall be Anaconda SEALTITE® Type CNP. Conduit shall be constructed of smooth inner thermoplastic PVC core with outer oil-resistant and sunlight resistant PVC outer cover. Conduit shall have nylon reinforcing layer between the core and outer cover. Conduit shall be assembled with approved fittings to provide liquid-tight raceway for wiring. Conduit shall be UL listed and CSA certified as a Type "A" non-metallic conduit and be used in applications requiring a temperature range of -4ºF to +140ºF (-20ºC to +60ºC). Conduit IP 67 rated when installed with approved end connectors.
Unit of Measure

Specifications

Type

CNP

Electrical Trade Size

1-1/2 in41 mm

Length

50 ft15.24 m

Packaging

Standard Carton

Inside Diameter

1.585 to 1.620 in40.259 to 41.148 mm

Outside Diameter

2.045 to 2.080 in51.943 to 52.832 mm

Approx. Inside Bend Radius

8.0 in203.2 mm

Approx. Weight per 100 ft

81 lbs36.74 kg

Color

Orange

Optional Colors

Gray

Note

Colors available on request.

Industry Certifications


UL Listed & CSA Certified



Cross-Reference #

6506-24-00 87502 LFNC-A LNM-P 15

Core Material

Polyvinyl Chloride (PVC)

Ingress Protection (IP) Rating

Ingress Protection (IP) 66/67

Jacket Material

Polyvinyl Chloride (PVC)

Jacket Benefits

Liquid Tight Oil Resistant

Installation

N/A

  • Conduit used with standard connectors for non-metallic conduit Type A for easy installation. IP 67 Rated when installed with approved connectors.
  • Approved for both exposed and concealed locations. Rated for temperature ranges of -4ºF to +140ºF (-20ºCto +60ºC).
  • Complies with UL Standard 1660 Type A conduit File No. E-75863; CSA C22.2 File No. LL15257; and NEC Article 356.
  • Easy to install and cuts easily.
  • Manufactured in a full range of trade sizes from 3/8" through 2".
  • Flexible, but tough; crush, abrasion and strain resistant. Where abrasion, physical abuse or constant flexing are a factor.

NEC Articles

N/A

  • Article 250.102 Equipment Bonding Jumpers
  • Article 250.134 (B) Equipment Grounding
  • Article 300.22 (D) Information Technology Equipment
  • Article 356 Liquid-Tight Flexible Nonmetallic Conduit (LFNC-A)
  • Article 501.10 (B) (2) Class I Div. 2
  • Article 502.10 (A) (2) and (B) (2) Class II Div. 1 & 2
  • Article 503.10 (A) (3) and (B) Class III Div. 1 & 2
  • Article 620.21 Elevator Wiring Methods
  • Article 645.5 (E) (2) Under Raised Floors

Application

N/A Where Abrasion or Physical Abuse are Factors, Constant Flexing or Movement
Temperature Range: -4ºF to +140ºF (-20ºC to +60ºC)