SHIELDTITE® Z1- EMI/EMP for High Level Shielding, Zero Halogen, Liquid Tight, Flexible, Metal Conduit (LFMC)
Specialty Conduit
Construction
- Constructed of continuously interlocked high shielding bronze core for exceptional shielding effectiveness
- Durable, abrasion resistant, smooth, flame retardant, sunlight resistant, LOW SMOKE, ZERO HALOGEN, TPU jacket resists heat, oil and chemical breakdown
Description
- Flexible bronze core liquid tight conduit
- Designed for applications needing superior EMI and EMP shielding
- Uses standard, liquid tight, conduit fittings for easy installation
- Available in cut sections with fittings installed, by special order
- Low Smoke and Halogen Free jacket
- Meets the demands of today’s higher temperature rated conductors
Specifications
- Bronze core with liquid tight PVC jacket
- Color: Gray
- Temperature range: -40°F to +176°F (-40°C to +80°C)
- UV (sunlight) resistant
- Corrosion resistant
- Special bronze core provides high-level shielding protection, meeting MIL-STD-1310H
- Bronze core provides shielding effectiveness of 81 dB to 119 dB at 1 kHz to 1 GHz
Applications
- Applications where high shielding is required
- Military, power generation and communications
Certification
Meets MIL-STD-1310H / RoHS WEEE COMPLIANTConstruction
Unit of Measure
Items |
/Asset/20 Shieldtite Z1.jpg 450200-0185 SHIELDTITE® Z1 - EMI/EMP for High Level Shielding Liquid-Tight Flexible Metal Conduit (LFMC) |
/Asset/20 Shieldtite Z1.jpg 450202-0185 SHIELDTITE® Z1 - EMI/EMP for High Level Shielding Liquid-Tight Flexible Metal Conduit (LFMC) |
/Asset/20 Shieldtite Z1.jpg 450204-0185 SHIELDTITE® Z1 - EMI/EMP for High Level Shielding Liquid-Tight Flexible Metal Conduit (LFMC) |
/Asset/20 Shieldtite Z1.jpg 450206-0185 SHIELDTITE® Z1 - EMI/EMP for High Level Shielding Liquid-Tight Flexible Metal Conduit (LFMC) |
/Asset/20 Shieldtite Z1.jpg 450208-0185 SHIELDTITE® Z1 - EMI/EMP for High Level Shielding Liquid-Tight Flexible Metal Conduit (LFMC) |
|||||
Description |
N/A
Thermoplastic PVC jacket |
|||||||||
Type | N/A SHIELDTITE® Z1 | |||||||||
Electrical Trade Size | N/A 3/8 in12 mm | N/A 1/2 in16 mm | N/A 3/4 in21 mm | N/A 1 in27 mm | N/A 1-1/4 in35 mm | |||||
Length | N/A Custom | |||||||||
Packaging | N/A Contact Anamet | |||||||||
Inside Diameter | N/A 0.485 to 0.505 in12.319 to 12.827 mm | N/A 0.622 to 0.642 in15.799 to 16.307 mm | N/A 0.815 to 0.835 in20.701 to 21.209 mm | N/A 1.041 to 1.066 in26.441 to 27.076 mm | N/A 1.370 to 1.395 in34.798 to 35.433 mm | |||||
Outside Diameter | N/A 0.690 to 0.710 in17.526 to 18.034 mm | N/A 0.820 to 0.840 in20.828 to 21.336 mm | N/A 1.030 to 1.050 in26.162 to 26.670 mm | N/A 1.290 to 1.315 in32.766 to 33.401 mm | N/A 1.630 to 1.660 in41.402 to 42.164 mm | |||||
Approx. Inside Bend Radius | N/A 3.0 in76.2 mm | N/A 3.0 in76.2 mm | N/A 4.0 in101.6 mm | N/A 4.0 in101.6 mm | N/A 4.5 in114.3 mm | |||||
Approx. Weight per 100 ft | N/A 24 lbs10.89 kg | N/A 28 lbs12.70 kg | N/A 42 lbs19.05 kg | N/A 56 lbs25.40 kg | N/A 75 lbs34.02 kg | |||||
Installation |
N/A
|
|||||||||
Color | N/A GRAY | |||||||||
Note |
N/A
Available in Random Lengths |
|||||||||
Application |
N/A
For High Level RFI and EMI Shielding |
|||||||||
Industry Certifications |
N/A
RoHS WEEE |
|||||||||
Core Material | N/A Bronze | |||||||||
Ingress Protection (IP) Rating | N/A Ingress Protection (IP) 66/67 | |||||||||
Jacket Material | N/A Thermoplastic Polyurethane (TPU) | |||||||||
Jacket Benefits | N/A Liquid Tight Zero Halogen | |||||||||
|